Triton Injector: Difference between revisions

From FSU Fox's Lab Wiki
Jump to navigation Jump to search
No edit summary
mNo edit summary
 
(One intermediate revision by the same user not shown)
Line 30: Line 30:
Ionizer Power Supply has Battery-backup and "10 second" interlock turn-down.  
Ionizer Power Supply has Battery-backup and "10 second" interlock turn-down.  
All other Power-supplies are turned down fast by interlock.
All other Power-supplies are turned down fast by interlock.
[[File:Source Diagram.png|frame|left|alt=Source Diagram|Source Diagram drawn by Ben Asher]]

Latest revision as of 14:30, 14 January 2024

The Triton Injector has components located at three different potentials with different systems:

Ground potential

  • Vacuum pumps: Titanium-Sublimation Pump (TSP) 2, Ion-getter pump (IGP)2, Turbo Pump, Roughing pump
  • Vacuum instrumentation: Ion-gauge, 2 TC, creating "Good vacuum 2" condition
  • Preaccelerator HV(-55 kV) supply
  • Fumehood Activity Monitor
  • Source Cooling

Interlock controller (monitoring Vacuum status from GND, -55 kV, monitoring cooling status, fumehood activity, AC power status) (providing shutdown signal for source Gate-valve, ion source power, Preaccelerator HV.)

-55 kV potential

  • Vacuum pumps: TSP 1, IGP 1
  • Vacuum instrumentation: Ion-gauge, TC, creating "Good vacuum 1" condition
  • Gate-valve controller, interlocked with GND-level controller

-65 kV potential

  • Ionizer Power supply
  • Extractor V Supply
  • Einzel Lens Supply
  • Cathode V Supply
  • Immersion-Lens V Supply
  • CS Boiler Supply (Variac)

All power is interlocked with GND-level Interlock controller: Ionizer Power Supply has Battery-backup and "10 second" interlock turn-down. All other Power-supplies are turned down fast by interlock.

Source Diagram
Source Diagram drawn by Ben Asher