Introduction
The interlock folder contains P1AM-100 code (which is Arduino MKX1000).
The Listen2Arduino.py is a script for listening the P1AM-100 output, and put the status, the tritium, Vaccum, and SubPump reading to the fsunuc.physics.fsu.edu database.
Setup using Arduino IDE 1.X
The P1AM.h library is needed.
Setup system service for the Listen2Arduino.py
copy the listen2P1AM.service to /etc/systemd/system/
run
sudo systemctl enable listen2P1AM.service
sudo systemctl start listen2P1AM.service
interlock database at fsunuc.physics.fsu.edu
database name : interlock