Update 'README.md'
This commit is contained in:
parent
12b717292b
commit
8742f7f284
37
README.md
37
README.md
|
@ -1,6 +1,6 @@
|
|||
# Introduction
|
||||
|
||||
The FSUDAQ is a GUI, supports 1 CAEN x725 and x730 digitizer with either DPP-PHA or DPP-PSD firmware. It uses the CEAN ROOT for the Graphical Interface.
|
||||
The FSUDAQ is a GUI, supports One (for now) CAEN x725 and x730 digitizer with either DPP-PHA or DPP-PSD firmware. It uses the CEAN ROOT for the Graphical Interface.
|
||||
|
||||
## Required Library
|
||||
|
||||
|
@ -16,7 +16,7 @@ FSUDAQ \
|
|||
├── Analysis \
|
||||
├── DAQ \
|
||||
├── elogText.txt \
|
||||
├── (Symbolic link to data folder) \
|
||||
├── (Symbolic link to experiment folder) \
|
||||
│ ├── data \
|
||||
│ │ └── *.fsu \
|
||||
│ ├── FSUDAQ.sh \
|
||||
|
@ -42,7 +42,7 @@ The rest of the files are for the GUI.
|
|||
|
||||
The Analysis folder stores all online analysis codes.
|
||||
|
||||
User should also make a symbolic link to the data folder.
|
||||
User should also make a symbolic link to the experiment folder.
|
||||
|
||||
The FSUDAQ.sh will be created when running the FSUDAQ for the 1st time. It stored the program settings.
|
||||
|
||||
|
@ -56,4 +56,35 @@ Go to the DAQ folder:
|
|||
|
||||
It will produce an executable FSUDAQ under the FSUDAQ, and FSUDAQDict_rdict.pcm.
|
||||
|
||||
# Usage
|
||||
|
||||
The FSUDAQ can be use as 2 ways. With digitizer open, run and take data, Without Digitizer open, open setting file and change it.
|
||||
|
||||
## Setup experiment folders
|
||||
|
||||
This can be done in 2 ways :
|
||||
|
||||
1. Using FSQDAQ. once the FSQDAQ run, it will create the FSUDAQ.sh if not exist. From the menu -> Settings -> Program Settings
|
||||
2. Edit the FSUDAQ.sh
|
||||
|
||||
The data folder can be inside FSUDAQ folder or anywhere.
|
||||
|
||||
## Open digitizers
|
||||
|
||||
Simply press the "Open Digitizers" button from the FSUDAQ. It wll scan all 4 ports of the fiber optics cards and 3 boards for each port. User can modify the MaxNBoard and MaxNPort in the code and re-compile.
|
||||
|
||||
When a digitizer is found, connection will be established. And setting files will be created at the settings folder inside the experiment folder with filename setting_XXX.bin, where XXX is the board serial number. If setting file is found, the setting will be use and program the digitizer.
|
||||
|
||||
### After opened digitizer
|
||||
|
||||
Once at least one digitizer is connected. The Board Setting and Channel Setting are avalible.
|
||||
|
||||
1. plot a single trace
|
||||
2. Continue run the digitizer without taking data. Can plot energy spectrum, count, or traces
|
||||
3. Take data. This will only take data, fast scanning the data, and dump it to *.fsu file. Files size limit is 2 GB.
|
||||
|
||||
## Open *.bin setting file
|
||||
|
||||
If no digitizer is open, user can open a setting file. once the setting file is open, the Board setting and Channel setting panels will open. User can change the settings.
|
||||
|
||||
User can use the Save button at the board setting to save the setting file into text format.
|