Split-Pole Spectrograph: Difference between revisions
(→Magnet) |
No edit summary |
||
Line 1: | Line 1: | ||
[[File:SPS Pictue Annotated.png|thumb|Annotated picture of the SE-SPS, An plain picture is | [[File:SPS Pictue Annotated.png|thumb|Annotated picture of the SE-SPS, An plain picture is here : [[:File:SPS Magnet.png]]]] | ||
The Split-Pole Spectrograph consists of a reaction chamber, a split-pole magnetic spectrograph, an ionization chamber, and a plastic scintillator. | The Split-Pole Spectrograph consists of a reaction chamber, a split-pole magnetic spectrograph, an ionization chamber, and a plastic scintillator. | ||
Line 6: | Line 6: | ||
== Magnet == | == Magnet == | ||
[[File:SPS | [[File:SPS Picture ray.png|thumb| SE-SPS COSY simulation. An plain picture is here [[:File:SPS Sketch With Cosy.png]]]] | ||
The SPS contains 2 dipole magnets: pole-1 and pole-2. | |||
== Focal plane detector == | == Focal plane detector == | ||
Line 13: | Line 14: | ||
There are two position-sensitive delay lines in the focal plane detector. By reconstructing the particle trajectory using the position information of both delay lines, the resolution can be enhanced by correcting for the kinematic shift of the reaction. | There are two position-sensitive delay lines in the focal plane detector. By reconstructing the particle trajectory using the position information of both delay lines, the resolution can be enhanced by correcting for the kinematic shift of the reaction. | ||
[[File:PID EDE annoteted.png|thumb]] | [[File:PID EDE annoteted.png|thumb]] | ||
[[File:XavgDiagram.png|thumb]] | [[File:XavgDiagram.png|thumb]] |
Revision as of 18:10, 27 May 2023
The Split-Pole Spectrograph consists of a reaction chamber, a split-pole magnetic spectrograph, an ionization chamber, and a plastic scintillator.
The magnet can be rotated from 0 to 55 degrees in the lab. The magnetic field has an upper limit of 14.5 kG.
Magnet
The SPS contains 2 dipole magnets: pole-1 and pole-2.
Focal plane detector
The focal plane detector consists of an ion chamber with a set of delay lines to detect the position of a particle along the focal plane and a plastic scintillator to detect the energy of the incoming particle. Using the energy loss of the particle through the ion chamber with the energy deposited in the scintillator, particles of different charges and masses can be identified.
There are two position-sensitive delay lines in the focal plane detector. By reconstructing the particle trajectory using the position information of both delay lines, the resolution can be enhanced by correcting for the kinematic shift of the reaction.
SABRE
The Silicon Array for Branching Ratio Experiments
SABRE is a silicon array designed around branching ratio experiments with the SPS. SABRE sits at backwards angles from the target, and covers roughly 30% of 4pi. SABRE has both thick and thin dead-layer detectors, with the thin dead-layer detectors capable of reaching ~200 keV thresholds for protons and deuterons.
https://www.sciencedirect.com/science/article/pii/S0168900221002837
SPS Experiment Guide
Media:SPS_Experiment_Guide.pdf
SPS Operating Procedures
I created this section as a place to store procedures for the chamber swaps, however, I expect there are other things we might want to document here. -p
Repositories
Contact
- Jeff Blackmon mailto:blackmon@lsu.edu
- Ingo
- who should be contacted?